IWB-094-22-IWB_Maintenance_OSS_2022-2023 Referenznummer der Bekanntmachung: IWB-094-22
Auftragsbekanntmachung – Sektoren
Dienstleistungen
Abschnitt I: Auftraggeber
Postanschrift:[gelöscht]
Ort: Oldenburg
NUTS-Code: DE943 Oldenburg (Oldenburg), Kreisfreie Stadt
Postleitzahl: 26122
Land: Deutschland
E-Mail: [gelöscht]
Internet-Adresse(n):
Hauptadresse: http://www.trianel-borkum.de/windpark/umspannplattform/
Abschnitt II: Gegenstand
IWB-094-22-IWB_Maintenance_OSS_2022-2023
Execution of corrosion protection and maintenance works on the steel structure of the offshore substation above the water line for the years 2022 - 2023 and optional prolongation until 2025.
The scope of Work shall comprise repair of the corrosion protection and other maintenance works at the steel structure of the offshore substation. The coating reparations shall comprise especially coating damages at the ceiling construction of the cellardeck, the mezzaninedeck, and the maindeck and the jacket structure above the water as well as spot repairs. In 2022, the different reparations shall compromise especially the main staircase from the maindeck to the helideck and the flanges of the J-Tubes at the level of the gangway of the jacket structure. Maintenance works shall especially include yearly inspections of the steel structure of the offshore substation above the water line as well as bolt exchanges and repair of flange seals.
IWB reserves the right for an optional prolongation of the contract for the years 2024 & 2025.
Abschnitt III: Rechtliche, wirtschaftliche, finanzielle und technische Angaben
A1.1) Provision of excerpt from the trade register or a register which is similar if applicable (entities which do not have to be registered are not required to provide an excerpt)
A1.2) Provision of the signed declaration about the non-fulfilment of competition exclusion reasons in order to 123 (1) and (4), 124 of the Act against Restraints on Competition (Kartellgesetz - GWB)
A2.1) Provision of a company (consortium) presentation including ownership structure, scope of services, manning level (separated in blue- / white-collar employees)
A2.2) Company accreditation: a valid certification of the company"s quality management system
(ISO 9001 or comparable)
A2.3) At minimum 2 employed FROSIO inspectors (or if external, each with at least 2 years of cooperation experience)
A3.1) At least 5 offshore projects in the last three years 2019 - 2021 in which coating works were carried out using rope access
A3.2) At least 5 offshore projects in the last three years 2019 - 2021 in which inspections on primary and secondary steel structures wew performed.
A3.3) At least 5 offshore projects in the last three years 2019 - 2021 in which mechanical work has been carried out on primary and secondary steel structures
Abschnitt IV: Verfahren
Abschnitt VI: Weitere Angaben
Bekanntmachungs-ID: CXP4Y0YRKQN
Postanschrift:[gelöscht]
Ort: Lüneburg
Postleitzahl: 21339